R series spray nozzles are externally mix nozzles. This means the liquid and air are mixed outside of air cap to produce complete atomized spray.
The liquid atomization is controlled by varying atomizing air and fan air pressures without changing liquid flow rates. The flat spray pattern is controlled by varying the fan air pressure in conjunction with the atomizing air. This is effective for high viscosity liquids, coatings and suspensions.
Tablet coating spray nozzle features a cylinder for controlled "on-off" operation. The cylinder controls a liquid clean-out/ Shut-off needle which also cleans the liquid orifice.
The R Series coating Spray Nozzle are a compact, precision nozzle.Incorporating independent controls of liquid atomizing air and fan air for fine tuning of spray capacity droplet size and spray patterns.It is available in a wide variety of spray setup that give a complete selection of flow rates and flat spray patterns.
Spray Nozzle |
Type |
RC |
Spray Type |
Airborne |
Air Atomized |
liquid orifice size range (Standard) |
mm |
0.8 - 1.5, (1.0) |
Solution Flow Rate (typical per nozzle) |
Liters/hour |
6 - 30 |
Atomizing Air Pressure Range |
bar |
0.7 - 3 |
Spray Width Pressure Range |
bar |
1.0 - 4.0 |
Maximum Compressed Air Pressure |
bar |
5.5 |
Compressed Air Consumption (maximum @ 2.0 bar) |
Nm³/hour |
10.5 |
Seal Material (standard) check compatibility for organic use |
FDA |
Approved |